Proportional Pressure Control Valve

PRODUCT TYPE: EDGProportional Pressure Control Valve
VALVE SIZE: 6mm
CONTROL METHOD: Proportional Pressure Control
APPLICATION Hydraulic Machines
CONNECTION TYPE: Subplate Connection
CONTROL METHOD: Hydraulic
PART NOS.: FT-EDG Series
APPROXIMATE WEIGHT: 2.00Kgs/4.4Lbs
RELATED PARTS:
FEATURE: 
– Hydraulic proportional pressure control valve
– Sensitive & Quick pressure response
– Reducing pipe sympathetic vibration

EDG proportional pressure control valve is combined with DC proportional solenoid and pressure control valve. The valve simplifies the hydraulic piping system to replace the complex conventional system of one pressure control section with one remote-controlled valve. The EDG proportional pressure control valve uses proportional solenoid which can generates no stage pressure at input electric current power. Its optimum features are good response, small piston shock while hydraulic pressure change and ability to reduce sympathetic vibration.

Finotek Proportional pressure control valve of EDG series uses for the automatic system with multi-level pressure states and high performance plastic injection machines.

EDG Valve Ordering Code

Example (Normal code): “FT-EDG 6 H 2X”
Explanation As Below:

FT-EDG6H2X
(1)(2)(3)(4)(5)

(1) Producer code= FT
(2) Proportional Pressure Control Valve: EDG
(3) Service Port Size= 6mm

(4) B= 0.5Mpa~7.0Mpa
  C= 1.0Mpa~16Mpa
  H= 1.2Mpa~25Mpa
(5) Valve series

EDG Valve Technical Information

Main Raw Materials: Casting Iron
Power: By hydraulic
Brand: Finotek or OEM
Max. Operation Pressure: 25Mpa
Max. Flow Rate: 2L/min.
Min. Flow Rate: 0.3L/min.

Rated Current: 800(mA)
Coil Resistance: 10Ω
Hysteresis: ≤2%
Repeatability: ≤1%
Oil Medium: Mineral oil as per DIN51 524, VDMA 24 568 or rapeseed oil, Viscosity 10 – 400 CST
Recommended Medium Filtration: ISO 4406 Standard, cleanliness class:20/18/15